Off-Grid HandbookPower and water for cabins and homesteads
About

Choosing Solar Panels: The Specs That Decide

The short answer

Wattage is the number on the box and it decides less than you think. Open circuit voltage decides whether your charge controller can use the panel at all: 37.44V on one panel and 22.79V on its smaller sibling, which is the difference between needing MPPT and not. Wiring changes the answer again, because two of the smaller panels in series reach a higher voltage than the large one. And voltage rises as it gets colder, so the figure that matters is never the one on the label.

Panels are the part of an off-grid system people compare on the fewest numbers. Wattage, price, and sometimes efficiency. Wattage tells you what the panel does at noon in a laboratory, and the two specifications that decide whether it suits your system are usually further down the page.

1. Open circuit voltage decides your charge controller

Voc is the voltage the panel produces with nothing connected to it. It is not the voltage it runs at, and it is the number that determines what you can wire the panel to.

The reason is the difference between the two controller types, covered in full on charge controllers:

  • A PWM controller connects the panel almost directly to the battery, dragging the panel down to battery voltage. Any voltage above that is simply lost.
  • An MPPT controller converts surplus voltage into extra current, so a high-voltage panel keeps its output.

That makes Voc a compatibility question rather than a preference. Two panels in the same manufacturer’s range, verified against their published figures:

200W N-Type 100W N-Type
Open circuit voltage 37.44V 22.79V
Short circuit current 6.85A 5.31A
Voltage at max power 31.03V 19.97V
Current at max power 6.46A 5.01A
Works with PWM on a 12V bank Not sensibly Yes
Sold as “12V/24V” 12V

The 200W is a 24V nominal panel whatever the listing says, and the same manufacturer’s European and Australian storefronts label that exact panel 24V. Put it on a 12V bank behind a PWM controller and you will pay for 200W and collect appreciably less. Behind MPPT it is fine.

This is the panel-side version of an argument this site makes repeatedly. A nominal label describes the market a product is sold into. The rating describes what it does. Where they disagree, the number wins. The same trap in switchgear is covered in why a 48V part is not for a 48V bank.

Buying the smaller panel does not by itself keep you on PWM

This is the part that catches people, and it falls straight out of the two tables above.

Arrangement Open circuit voltage Short circuit current
One 200W 37.44V 6.85A
Two 100W in parallel 22.79V 10.62A
Two 100W in series 45.58V 5.31A

Series wiring adds voltages. Two 100W panels in series reach 45.58V, which is higher than the single 200W panel they were bought instead of. Someone who chose the smaller panel specifically to stay PWM-compatible, and then wired the pair in series because that is the usual off-grid advice, has gone further from PWM than if they had bought the 200W in the first place.

Parallel keeps the voltage at 22.79V and doubles the current instead, which is what preserves PWM compatibility, at the cost of heavier cable between array and controller. That trade is the subject of the series and parallel section on the panels page.

So the panel and the wiring decide this together. Neither one alone tells you whether your controller can use the array.

2. Voltage rises when it gets cold

Published Voc is measured at 25°C. Panels produce more voltage as they get colder, and a cold clear morning is exactly when an off-grid array is doing its best work.

So the figure your charge controller has to survive is not the Voc on the datasheet. It is the Voc at the coldest temperature the array will ever see, which is higher, and it is why controllers carry a maximum PV input voltage well above any panel’s nameplate.

Every manufacturer publishes a temperature coefficient for voltage to let you work this out. Use theirs rather than a rule of thumb, because the coefficient differs between cell technologies, and get the answer right before wiring panels in series. Series wiring adds the voltages together, so a string that is comfortable in July can exceed a controller’s input rating on the coldest morning of the year. That is a failure that destroys the controller rather than merely disappointing you.

3. Module efficiency, not cell efficiency

Panels are advertised on cell efficiency. The number that describes the panel is module efficiency, and it is always lower, because a module is not all cells: it includes the frame, the gaps, and the margins.

Both panels above are built from 25% cells. As modules they are 20.7% and 20.0%. All four numbers are true, and only two of them tell you how much power comes off a given area of roof.

You can check a module efficiency claim yourself, which is worth doing because it is the number most often quietly inflated. Multiply the panel’s length by its width to get its area in square meters, divide the rated wattage by that, then divide by 1000. The 100W panel is 865 by 578 mm, so 0.5 m2 exactly, and 100W over half a square meter is 200 W/m2, which is 20.0%. If that arithmetic does not land on the published figure, one of the numbers is wrong.

Efficiency is watts per square meter, not watts per dollar. That matters less than people expect:

  • On open ground, where you can add another panel, the cheaper panel per watt usually wins. Efficiency is close to irrelevant.
  • On a fixed roof, a van, a boat, a small cabin, the area is the constraint and efficiency decides whether the system fits at all. This is the only situation where paying for efficiency is straightforwardly correct.

Work out the array size you need from your loads with the system sizing calculator first. Then find out whether it fits. Doing it the other way around produces a roof full of panels that does not match the load.

4. Temperature coefficient

The other temperature number, and this one costs you output rather than threatening equipment.

Panels lose power as they heat up, and a panel in full sun runs far hotter than the air around it. A coefficient of -0.29%/°C means roughly a third of a percent lost for every degree above 25°C. On a still summer day a panel at 55°C is down about 9% before anything else in the system has done anything wrong.

Lower is better, and it is one of the genuine arguments for N-type cells over older p-PERC construction. It is also why a hot climate does not automatically mean a better solar site, which climate considerations covers alongside the opposite problem.

5. The things that decide the install rather than the output

Dimensions and weight, because the mount and the roof have opinions. The 200W above is 1262 by 764 mm and 10.6 kg.

Ingress protection. IP65 on the junction box and IP67 on the connectors is the normal standard for a panel expected to live outdoors permanently.

Mechanical load ratings. 2400Pa wind and 5400Pa snow on this one. If you are somewhere with real snow, that second figure is not decoration, and neither is the tilt angle that sheds it.

The warranty, which has two halves. A material and workmanship warranty covering the panel failing, commonly 10 years, and a separate output warranty covering gradual degradation, commonly 25 years at 80%. The long number in the advertising is the second one. It does not mean the panel is guaranteed to still be there in 25 years, only that if it is, it should still make 80%.

What to buy

Disclosure: This page contains affiliate links. If you buy through them I may earn a commission, at no extra cost to you. This never affects which products I recommend or what I say about them.

As with the batteries guide, this list is limited to products whose governing specifications have been read from the manufacturer instead of a retail listing. The scope note at the bottom says what that leaves out.

Between the two, the 200W is the better panel and the 100W is the more compatible one. If MPPT is already in the design, or is going to be, take the 200W: it is more efficient per square meter, lighter per watt, and one panel replaces two sets of brackets and connectors. The 100W earns its place when the controller is fixed, the roof is awkwardly shaped, or the array has to grow in smaller steps than 200W at a time.

Scope, and what this guide does not do

One manufacturer is not a market. Renogy is here because their published data is complete enough to check and because I run their panels. That is a starting point, not a survey, and a guide that pretended otherwise would be worth less than an honest short one. More will be added as their datasheets are actually read.

Panels are the most commoditized part of a solar system, which cuts both ways. It means brand matters less here than it does for a battery or an inverter, and a well specified panel from a manufacturer who publishes real numbers is usually a fine choice regardless of the badge. It also means the specification table is genuinely the whole story, which is why this page is mostly about how to read one.

Specifications last verified . Every specification quoted here was read at the manufacturer, from the datasheet, manual or specification tab, and never from a retail listing, which routinely omits the figure that decides the choice. That keeps each comparison small: I would rather name three products I can check than thirty I cannot. No price is shown beside anything I recommend, and prices are not tracked, so check the current price at the retailer. Nothing here was supplied free, no manufacturer has any say in what appears, and where I own a product its card says how many and exactly which variant. A guide describes components, not your system: whether one fits depends on your loads, your worst month of sun and how long you must run without any, which is what the calculators work out.

Common questions

How many solar panels do I need for an off-grid cabin?
It follows from your daily energy use and the peak sun hours of the worst month the system has to work in, not from the size of the roof. The system sizing calculator on this site works out the array wattage from a load list, and the worked project pages show complete systems from a shed up to a full-time homestead.
What is open circuit voltage and why does it matter?
Voc is the voltage a panel produces with nothing connected. It matters because it decides which charge controller can use the panel. A PWM controller pulls the panel down to battery voltage, so a high-voltage panel on a 12V bank through PWM throws away the difference. An MPPT controller converts the excess voltage into current instead and keeps it.
Can I use a 200W panel on a 12V system?
Usually yes, but check the open circuit voltage first. Many 200W panels sit near 37V open circuit, which is a 24V nominal panel whatever the listing says. On a 12V bank it needs an MPPT controller to be worth buying. Panels sold as 12V typically publish Voc under about 25V and work with either controller type.
Is a higher efficiency panel worth paying for?
Only if area is the constraint. Efficiency describes watts per square meter, not watts per dollar, so on open ground the cheaper panel usually wins. On a van roof or a small cabin roof, where the space is fixed and the load is not, efficiency is what decides whether the system fits at all.
Why is the cell efficiency higher than the panel efficiency?
Because a panel is not all cells. Module efficiency counts the whole panel including the frame and the gaps between cells, so it is always the lower and the more honest number. A panel advertised at 25% cell efficiency may be about 21% as a module, and both figures can be true at once.